SLLS983J June   2009  – September 2019 ISO1050

PRODUCTION DATA.  

  1. Features
  2. Applications
  3. Description
    1.     Device Images
      1.      Simplified Schematic
  4. Revision History
  5. Pin Configuration and Functions
    1.     Pin Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics: Supply Current
    6. 6.6  Electrical Characteristics: Driver
    7. 6.7  Electrical Characteristics: Receiver
    8. 6.8  Switching Characteristics: Device
    9. 6.9  Switching Characteristics: Driver
    10. 6.10 Switching Characteristics: Receiver
    11. 6.11 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 CAN Bus States
      2. 8.3.2 Digital Inputs and Outputs
      3. 8.3.3 Protection Features
        1. 8.3.3.1 TXD Dominant Time-Out (DTO)
        2. 8.3.3.2 Thermal Shutdown
        3. 8.3.3.3 Undervoltage Lockout and Fail-Safe
        4. 8.3.3.4 Floating Pins
        5. 8.3.3.5 CAN Bus Short-Circuit Current Limiting
    4. 8.4 Device Functional Modes
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
        1. 9.2.2.1 Bus Loading, Length and Number of Nodes
        2. 9.2.2.2 CAN Termination
      3. 9.2.3 Application Curve
  10. 10Power Supply Recommendations
    1. 10.1 General Recommendations
    2. 10.2 Power Supply Discharging
  11. 11Layout
    1. 11.1 Layout Guidelines
      1. 11.1.1 PCB Material
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Trademarks
    3. 12.3 Electrostatic Discharge Caution
    4. 12.4 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • DUB|8
  • DW|16
サーマルパッド・メカニカル・データ
発注情報

Revision History

Changes from I Revision (September 2014) to J Revision

  • Changed VDE standard name From: DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 To: DIN VDE V 0884-11:2017-01 in FeaturesGo
  • Deleted 'Component Acceptance Notice 5 A' from CSA bullet in FeaturesGo
  • Changed inverting output label From: CANH To: CANL in Figure 16Go
  • Changed VDE standard name From: DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 To: DIN VDE V 0884-11:2017-01 in Table 3Go
  • Changed VISO PARAMETER description From: 'ISO1050DUB - Double Protection' To: 'ISO1050DUB - Single Protection' in Table 3Go
  • Updated Regulatory Information in Table 6Go
  • Changed UL 1577 rating for ISO1050DUB From: '2500 VRMS Double Protection' To: '2500 VRMS Single Protection' in Table 6Go
  • Deleted UL 1577 'Double Protection' rating of 3500 VRMS for ISO1050DW in Table 6Go
  • Added Power Supply Discharging section and SN6505 reference to Power Supply RecommendationsGo
  • Added SN6505x data sheet link to 'Transformer Driver for Isolated Power Supplies' in Documentation Support sectionGo

Changes from H Revision (June 2013) to I Revision

  • Added Pin Configuration and Functions section, ESD Ratings table, Feature Description section, Device Functional Modes, Application and Implementation section, Power Supply Recommendations section, Layout section, Device and Documentation Support section, and Mechanical, Packaging, and Orderable Information section Go

Changes from G Revision (March 2013) to H Revision

  • Changed title From: LIFE EXPECTANCY vs WORKING VOLTAGE (ISO1050DW To: LIFE EXPECTANCY vs WORKING VOLTAGE (ISO1050DUB)Go

Changes from F Revision (January 2013) to G Revision

  • Clarified clearance and creepage measurement method in ISOLATOR CHARACTERISTICSGo
  • Clarified test methods for voltage ratings in INSULATION CHARACTERISTICSGo
  • Changed UL Single Protection Certification pending to Single Protection in REGULATORY INFORMATION SECTION (certificate available)Go

Changes from E Revision (December 2011) to F Revision

  • Deleted ISO1050L deviceGo
  • Deleted ISO1050LDW from Features listGo
  • Deleted ISO1050LDW in first paragraph of DESCRIPTIONGo
  • Added the PIN FUNCTIONS sectionGo
  • Added Note 1 to the DRIVER SWITCHING CHARACTERISTICS tableGo
  • Deleted ISO1050LDW from INSULATION CHARACTERISTICSGo
  • Deleted ISO1050LDW from REGULATORY INFORMATIONGo
  • Added the FUNCTIONAL DESCRIPTION sectionGo
  • Deleted ISO1050LDW from LIFE EXPECTANCY vs WORKING VOLTAGE Go
  • Deleted 40V from the CANH and CANL input diagrams and output diagrams in the EQUIVALENT I/O SCHEMATICS Go
  • Changed the APPLICATION INFORMATION sectionGo
  • Changed the BUS LOADING, LENGHT AND NUMBER OF NODES sectionGo
  • Added the CAN TERMINATION sectionGo

Changes from D Revision (June 2011) to E Revision

  • Added device ISO1050LGo
  • Changed (DW Package) in the Features list to (ISO1050DW)Go
  • Changed (DUB Package) in the Features list to (ISO1050DUB and ISO1050LDW)Go
  • Deleted IEC 60950-1 from the CSA Approvals Feature bulletGo
  • From: IEC 60601-1 (Medical) and CSA Approvals Pending To: IEC 60601-1 (Medical) and CSA Approved Go
  • Added Feature - 5 KVRMS Reinforced..Go
  • Changed DW Package to ISO105DW and DUB package to ISO1050DUB and ISO1050LDW in the first paragraph of DESCRIPTIONGo
  • Added Note 1 to the INSULATION CHARACTERISTICS tableGo
  • Changed VIORM From: 8-DUB Package to ISO1050DUB and ISO1050LDW Go
  • Changed VIORM From: 16-DW to ISO1050DW Go
  • Changed the VISO Isolation voltage per UL section of the INSULATION CHARACTERISTICS table.Go
  • Changed the IEC 60664-1 Ratings TableGo
  • Changed the REGULATORY INFORMATION tableGo
  • Changed From: File Number: 220991 (Approval Pending) To: File Number: 220991Go
  • Changed in note (1) 3000 to 2500 and 6000 to 5000Go
  • Changed in LIFE EXPECTANCY vs WORKING VOLTAGE (8-DUB PACKAGE TO: LIFE.....(ISO1050DW and ISO1050LDW)Go

Changes from C Revision (July 2010) to D Revision

  • Changed the SUPPLY CURRENT table for ICC1 1st row From: Typ = 1 To: 1.8 and MAX = 2 To: 2.8Go
  • Changed the SUPPLY CURRENT table for ICC1 2nd row From: Typ = 2 To: 2.8 and MAX = 3 To: 3.6Go
  • Changed the REGULATORY INFORMATION tableGo

Changes from B Revision (June 2009) to C Revision

  • Changed the IEC 60747-5-2 Features bullet From: DW package Approval Pending To: VDE approved for both DUB and DW packagesGo
  • Changed the Minimum Internal Gap value from 0.008 to 0.014 in the Isolator Characteristics tableGo
  • Changed VIORM Specification From: 1300 To: 1200 per VDE certificationGo
  • Changed VPR Specification From 2438 To: 2250Go
  • Added the Bus Loading paragraph to the Application Information sectionGo

Changes from A Revision (Sept 2009) to B Revision

  • Added information that IEC 60747-5-2 and IEC61010-1 have been approvedGo
  • Changed DW package from preview to production dataGo
  • Added Insulation Characteristics and IEC 60664-1 Ratings tablesGo
  • Added IEC file numberGo

Changes from * Revision (June 2009) to A Revision

  • Added Typical 25-Year Life at Rated Working Voltage to FeaturesGo
  • Added LIFE EXPECTANCY vs WORKING VOLTAGE sectionGo