JAJSGC8B October   2018  – January 2020 TPS25982

PRODUCTION DATA.  

  1. 特長
  2. アプリケーション
  3. 概要
    1.     概略回路図
  4. 改訂履歴
  5. デバイス比較表
  6. 概要 (続き)
  7. Pin Configuration and Functions
    1.     Pin Functions
  8. Specifications
    1. 8.1 Absolute Maximum Ratings
    2. 8.2 ESD Ratings
    3. 8.3 Recommended Operating Conditions
    4. 8.4 Thermal Information
    5. 8.5 Electrical Characteristics
    6. 8.6 Timing Requirements
    7. 8.7 Switching Characteristics
    8. 8.8 Typical Characteristics
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1 Undervoltage Protection (UVLO and UVP)
      2. 9.3.2 Overvoltage Protection (OVP)
      3. 9.3.3 Inrush Current, Overcurrent, and Short-Circuit Protection
        1. 9.3.3.1 Slew Rate and Inrush Current Control (dVdt)
        2. 9.3.3.2 Circuit Breaker
        3. 9.3.3.3 Active Current Limiting
        4. 9.3.3.4 Short-Circuit Protection
      4. 9.3.4 Overtemperature Protection (OTP)
      5. 9.3.5 Analog Load Current Monitor (IMON)
      6. 9.3.6 Power Good (PG)
      7. 9.3.7 Load Detect/Handshake (LDSTRT)
    4. 9.4 Fault Response
    5. 9.5 Device Functional Modes
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application: Standby Power Rail Protection in Datacenter Servers
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
        1. 10.2.2.1 Device Selection
        2. 10.2.2.2 Setting the Current Limit Threshold: RILIM Selection
        3. 10.2.2.3 Setting the Undervoltage Lockout Set Point
        4. 10.2.2.4 Choosing the Current Monitoring Resistor: RIMON
        5. 10.2.2.5 Setting the Output Voltage Ramp Time (TdVdt)
          1. 10.2.2.5.1 Case 1: Start-Up Without Load: Only Output Capacitance COUT Draws Current
          2. 10.2.2.5.2 Case 2: Start-Up With Load: Output Capacitance COUT and Load Draw Current
        6. 10.2.2.6 Setting the Load Handshake (LDSTRT) Delay
        7. 10.2.2.7 Setting the Transient Overcurrent Blanking Interval (tITIMER)
        8. 10.2.2.8 Setting the Auto-Retry Delay and Number of Retries
      3. 10.2.3 Application Curves
    3. 10.3 System Examples
      1. 10.3.1 Optical Module Power Rail Path Protection
        1. 10.3.1.1 Design Requirements
        2. 10.3.1.2 Device Selection
        3. 10.3.1.3 External Component Settings
        4. 10.3.1.4 Voltage Drop
        5. 10.3.1.5 Application Curves
      2. 10.3.2 Input Protection for 12-V Rail Applications: PCIe Cards, Storage Interfaces and DC Fans
  11. 11Power Supply Recommendations
    1. 11.1 Transient Protection
    2. 11.2 Output Short-Circuit Measurements
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
  13. 13デバイスおよびドキュメントのサポート
    1. 13.1 ドキュメントのサポート
      1. 13.1.1 関連資料
        1. 13.1.1.1 関連リンク
    2. 13.2 ドキュメントの更新通知を受け取る方法
    3. 13.3 コミュニティ・リソース
    4. 13.4 商標
    5. 13.5 静電気放電に関する注意事項
    6. 13.6 Glossary
  14. 14メカニカル、パッケージ、および注文情報

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

特長

  • 広い入力電圧範囲:2.7V~24V
    • 絶対最大定格:30V
  • 低いオン抵抗:RON = 2.7mΩ (標準値)
  • 可変電流制限スレッショルド
    • 範囲:2A~15A
    • 精度:±8% (ILIM > 5A での標準値)
  • サーキット・ブレーカと電流リミッタのオプション
  • 可変の過電流ブランキング・タイマ
    • トリップなしに負荷過渡を処理
  • 正確な電流モニタ出力
    • ±1.5% (25℃、IOUT > 3A での標準値)
  • フォルト応答をユーザーが構成可能
    • ラッチ・オフまたは自動再試行
    • 再試行回数 (有限または無限)
    • 再試行間隔
  • 堅牢な短絡保護機能
    • 高速トリップ応答時間:400ns 未満 (標準値)
    • 100 万回の電源短絡イベントでテスト済み
    • ライン過渡への耐性 - 不要なトリップなし
  • 可変出力スルー・レート (dVdt) 制御
  • 可変の低電圧誤動作防止
  • 過電圧誤動作防止 (固定 3.7V、7.6V、16.9V、および OVLO なしのオプション)
  • 過熱保護機能を内蔵
  • パワー・グッド表示
  • 可変の負荷検出およびハンドシェイク・タイマ
  • UL 2367 認定
    • ファイル番号E339631
    • RILIM ≥ 182Ω
  • IEC 62368 CB 認定
  • 小さなフットプリント:4mm × 4mm の QFN パッケージ