8.3.1.2.2 Trigger In Mode
Trigger In mode provides higher level of control to the user for displaying patterns. In this mode, user controls when to display the pattern by sending an external trigger signal to the DLPC3478 controller. The DLPC3478 controller outputs a Pattern Ready signal to let the user know when DLPC3478 controller is ready to accept the external trigger signal.
DLPC3478 controller sets the Pattern Ready signal high to denote that the DLPC3478 controller is ready to accept Trigger In signal.
The user sends the external trigger input signal to the DLPC3478 controller to begin the display of the next pattern with tExposure (exposure time), tDarkPre and tDarkPost (dark time).
Blue LED is configured to be ON for each pattern.
TRIG_OUT_1 (Pattern Set Trigger) is configured active high polarity and will have a minimum pulse width of 20 microseconds. TRIG_OUT_1 delay (tD1) is configured with respect to external trigger input (TRIG_IN).