SNAS187D February   2003  – January 2016 LMX2430 , LMX2433 , LMX2434

PRODUCTION DATA.  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Description continued
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 Recommended Operating Conditions
    3. 7.3 Thermal Information
    4. 7.4 Electrical Characteristics
    5. 7.5 Timing Requirements
    6. 7.6 Typical Characteristics
      1. 7.6.1 Sensitivity
      2. 7.6.2 Charge Pump
      3. 7.6.3 Input Impedance
  8. Parameter Measurement Information
    1. 8.1 Bench Test Setups
      1. 8.1.1 LMX243x Charge-Pump Test Setup
      2. 8.1.2 Charge-Pump Current Specification Definitions
        1. 8.1.2.1 Charge-Pump Output Current Variation vs Charge-Pump Output Voltage
        2. 8.1.2.2 Charge-Pump Sink Current vs Charge-Pump Output Source Current Mismatch
        3. 8.1.2.3 Charge-Pump Output Current Variation vs Temperature
      3. 8.1.3 LMX243x FinRF Sensitivity Test Setup
      4. 8.1.4 LMX243x OSCin Sensitivity Test Setup
      5. 8.1.5 LMX243x FinRF Input Impedance Test Setup
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1  Reference Oscillator Input
      2. 9.3.2  Reference Dividers (R Counters)
      3. 9.3.3  Prescalers
      4. 9.3.4  Programmable Feedback Dividers (N Counters)
      5. 9.3.5  Phase / Frequency Detectors
        1. 9.3.5.1 Phase Comparator and Internal Charge-Pump Characteristics
      6. 9.3.6  Charge Pumps
      7. 9.3.7  Microwire Serial Interface
      8. 9.3.8  Multi-Function Outputs
        1. 9.3.8.1 Push-Pull Analog Lock-Detect Output
        2. 9.3.8.2 Open-Drain Analog Lock-Detect Output
        3. 9.3.8.3 Digital Filtered Lock-Detect Output
        4. 9.3.8.4 Reference Divider and Feedback Divider Output
      9. 9.3.9  Fastlock Output
      10. 9.3.10 Counter Reset
    4. 9.4 Device Functional Modes
      1. 9.4.1 Power Control
        1. 9.4.1.1 Synchronous Power-Down Mode
        2. 9.4.1.2 Asynchronous Power-Down Mode
    5. 9.5 Programming
      1. 9.5.1 Microwire Interface
      2. 9.5.2 Control Register Location
    6. 9.6 Register Maps
      1. 9.6.1 Control Register Content Map
      2. 9.6.2 R0 Register
        1. 9.6.2.1 RF_R[14:0] - RF Synthesizer Programmable Reference Divider (R Counter) (R0[17:3])
        2. 9.6.2.2 RF_CPP - RF Synthesizer Phase Detector Polarity (R0[18])
        3. 9.6.2.3 RF_CPG - RF Synthesizer Charge-Pump Current Gain (R0[19])
        4. 9.6.2.4 RF_CPT - RF Synthesizer Charge-Pump Tri-State (R0[20])
        5. 9.6.2.5 RF_RST - RF Synthesizer Counter Reset (R0[21])
      3. 9.6.3 R1 Register
        1. 9.6.3.1 LMX243x RF Synthesizer Swallow Counter
          1. 9.6.3.1.1 RF_A[3:0] - LMX2430/33 RF Synthesizer Swallow Counter (A Counter) (R1[6:3])
          2. 9.6.3.1.2 RF_A[4:0] - LMX2434 RF Synthesizer Swallow Counter (A Counter) (R1[7:3])
        2. 9.6.3.2 LMX243x RF Synthesizer Programmable Binary Counter
          1. 9.6.3.2.1 RF_B[14:0] - LMX2430/33 RF Synthesizer Programmable Binary Counter (B Counter) (R1[21:7])
          2. 9.6.3.2.2 RF_B[13:0] - LMX2434 RF Synthesizer Programmable Binary Counter (B Counter) (R1[21:8])
        3. 9.6.3.3 LMX243x RF Synthesizer Prescaler Select
          1. 9.6.3.3.1 RF_P - LMX2430/33 RF Synthesizer Prescaler Select (R1[22])
          2. 9.6.3.3.2 RF_P - LMX2434 RF Synthesizer Prescaler Select (R1[22])
        4. 9.6.3.4 RF_PD - RF Synthesizer Power Down (R1[23])
      4. 9.6.4 R2 Register
        1. 9.6.4.1 RF_TOC[0:11] - RF Synthesizer Time-Out Counter (R2[14:3])
        2. 9.6.4.2 R3 Register
          1. 9.6.4.2.1 IF_R[14:0] - IF Synthesizer Programmable Reference Divider (R Counter) (R3[17:3])
          2. 9.6.4.2.2 IF_CPP - IF Synthesizer Phase Detector Polarity (R3[18])
          3. 9.6.4.2.3 IF_CPG - IF Synthesizer Charge-Pump Current Gain (R3[19])
          4. 9.6.4.2.4 IF_CPT - IF Synthesizer Charge-Pump Tri-State (R3[20])
          5. 9.6.4.2.5 IF_RST - IF Synthesizer Counter Reset (R3[21])
      5. 9.6.5 R4 Register
        1. 9.6.5.1 IF_A[3:0] - IF Synthesizer Swallow Counter (A Counter) (R4[6:3])
        2. 9.6.5.2 IF_B[13:0] - IF Synthesizer Programmable Binary Counter (B Counter) (R4[20:7])
          1. 9.6.5.2.1 IF_P - IF Synthesizer Prescaler Select (R4[22])
        3. 9.6.5.3 IF_PD - IF Synthesizer Power Down (R4[23])
      6. 9.6.6 R5 Register
        1. 9.6.6.1 IF_TOC[0:11] - IF Synthesizer Time-Out Counter (R5[14:3])
      7. 9.6.7 MUX[3:0] - Multifunction Output Select (R3[23:22]:R0[23:22])
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
      3. 10.2.3 Application Curves
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Device Support
      1. 13.1.1 Device Nomenclature
        1. 13.1.1.1 List of Definitions
    2. 13.2 Related Links
    3. 13.3 Community Resources
    4. 13.4 Trademarks
    5. 13.5 Electrostatic Discharge Caution
    6. 13.6 Glossary
  14. 14Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

13 Device and Documentation Support

13.1 Device Support

13.1.1 Device Nomenclature

13.1.1.1 List of Definitions

     fCOMP:RF or IF phase detector comparison frequency
     Fin:RF or IF input frequency
     A:RF_A or IF_A counter value
     B:RF_B or IF_B counter value
     P:Preset modulus of the dual moduIus prescaler

    LMX2430 RF synthesizer: P = 8 or 16

    LMX2433 RF synthesizer: P = 8 or 16

    LMX2434 RF synthesizer: P = 16 or 32

    LMX243x IF synthesizer: P = 8 or 16

13.2 Related Links

The table below lists quick access links. Categories include technical documents, support and community resources, tools and software, and quick access to sample or buy.

Table 42. Related Links

PARTS PRODUCT FOLDER SAMPLE & BUY TECHNICAL DOCUMENTS TOOLS & SOFTWARE SUPPORT & COMMUNITY
LMX2430 Click here Click here Click here Click here Click here
LMX2433 Click here Click here Click here Click here Click here
LMX2434 Click here Click here Click here Click here Click here

13.3 Community Resources

The following links connect to TI community resources. Linked contents are provided "AS IS" by the respective contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of Use.

    TI E2E™ Online Community TI's Engineer-to-Engineer (E2E) Community. Created to foster collaboration among engineers. At e2e.ti.com, you can ask questions, share knowledge, explore ideas and help solve problems with fellow engineers.
    Design Support TI's Design Support Quickly find helpful E2E forums along with design support tools and contact information for technical support.

13.4 Trademarks

E2E is a trademark of Texas Instruments.

PLLatinum is a trademark of TI.

All other trademarks are the property of their respective owners.

13.5 Electrostatic Discharge Caution

esds-image

These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates.

13.6 Glossary

SLYZ022TI Glossary.

This glossary lists and explains terms, acronyms, and definitions.