JAJSGE0C JANUARY   2014  – October 2018 TPS40425

PRODUCTION DATA.  

  1. 特長
  2. アプリケーション
  3. 概要
    1.     Device Images
      1. 3.1 アプリケーション概略図 (デュアル出力)
  4. 改訂履歴
  5. Pin Configuration and Functions
    1.     Pin Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 Handling Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1  Asynchronous Pulse Injection (API)
      2. 7.3.2  Adaptive Voltage Scaling (AVS)
      3. 7.3.3  Switching Frequency and Synchronization
      4. 7.3.4  Voltage Reference
      5. 7.3.5  Output Voltage and Remote Sensing Amplifier
      6. 7.3.6  Current Sensing and Temperature Sensing Modes
        1. 7.3.6.1 Non Smart-Power Operation
        2. 7.3.6.2 Smart-Power Operation.
      7. 7.3.7  Current Sensing
      8. 7.3.8  Temperature Sensing
      9. 7.3.9  Current Sharing
      10. 7.3.10 Linear Regulators
      11. 7.3.11 Power Sequence Between TPS40425 Device and Power Stage
      12. 7.3.12 PWM Signal
        1. 7.3.12.1 PWM Behavior During Soft-start Operation
      13. 7.3.13 Startup and Shutdown
      14. 7.3.14 Pre-Biased Output Start-up
      15. 7.3.15 PGOOD Indication
      16. 7.3.16 Overcurrent Protection
      17. 7.3.17 Overvoltage/Undervoltage Protection
      18. 7.3.18 Overtemperature Fault Protection
      19. 7.3.19 Input Undervoltage Lockout (UVLO)
      20. 7.3.20 Fault Communication
      21. 7.3.21 Fault Protection Summary
    4. 7.4 Device Functional Modes
    5. 7.5 Programming
      1. 7.5.1 Multi-Phase Applications
    6. 7.6 Register Maps
      1. 7.6.1 PMBus General Description
      2. 7.6.2 PMBus Functionality
        1. 7.6.2.1 PMBus Address
        2. 7.6.2.2 PMBus Connections
        3. 7.6.2.3 PMBus Data Format
        4. 7.6.2.4 PMBus Output Voltage Adjustment
          1. 7.6.2.4.1 No Margin Voltage
          2. 7.6.2.4.2 Margin High Voltage State
          3. 7.6.2.4.3 Margin Low State
      3. 7.6.3 Reading the Output Current
      4. 7.6.4 Soft-Start Time
      5. 7.6.5 Turn-On/Turn-Off Delay and Sequencing
    7. 7.7 Supported PMBus Commands
      1. 7.7.1  PAGE (00h)
      2. 7.7.2  OPERATION (01h)
      3. 7.7.3  ON_OFF_CONFIG (02h)
      4. 7.7.4  CLEAR_FAULTS (03h)
      5. 7.7.5  WRITE_PROTECT (10h)
      6. 7.7.6  STORE_USER_ALL (15h)
      7. 7.7.7  RESTORE_USER_ALL (16h)
      8. 7.7.8  CAPABILITY (19h)
      9. 7.7.9  VOUT_MODE (20h)
      10. 7.7.10 VIN_ON (35h)
      11. 7.7.11 VIN_OFF (36h)
      12. 7.7.12 IOUT_CAL_GAIN (38h)
      13. 7.7.13 IOUT_CAL_OFFSET (39h)
      14. 7.7.14 IOUT_OC_FAULT_LIMIT (46h)
      15. 7.7.15 IOUT_OC_FAULT_RESPONSE (47h)
      16. 7.7.16 IOUT_OC_WARN_LIMIT (4Ah)
      17. 7.7.17 OT_FAULT_LIMIT (4Fh)
      18. 7.7.18 OT_WARN_LIMIT (51h)
      19. 7.7.19 TON_RISE (61h)
      20. 7.7.20 STATUS_BYTE (78h)
      21. 7.7.21 STATUS_WORD (79h)
      22. 7.7.22 STATUS_VOUT (7Ah)
      23. 7.7.23 STATUS_IOUT (7Bh)
      24. 7.7.24 STATUS_TEMPERATURE (7Dh)
      25. 7.7.25 STATUS_CML (7Eh)
      26. 7.7.26 STATUS_MFR_SPECIFIC (80h)
      27. 7.7.27 READ_VOUT (8Bh)
      28. 7.7.28 READ_IOUT (8Ch)
      29. 7.7.29 READ_TEMPERATURE_2 (8Eh)
      30. 7.7.30 PMBus_REVISION (98h)
      31. 7.7.31 MFR_SPECIFIC_00 (D0h)
      32. 7.7.32 MFR_SPECIFIC_04 (VREF_TRIM) (D4h)
      33. 7.7.33 MFR_SPECIFIC_05 (STEP_VREF_MARGIN_HIGH) (D5h)
      34. 7.7.34 MFR_SPECIFIC_06 (STEP_VREF_MARGIN_LOW) (D6h)
      35. 7.7.35 MFR_SPECIFIC_07 (PCT_VOUT_FAULT_PG_LIMIT) (D7h)
      36. 7.7.36 MFR_SPECIFIC_08 (SEQUENCE_TON_TOFF_DELAY) (D8h)
      37. 7.7.37 MFR_SPECIFIC_16 (COMM_EEPROM_SPARE) (E0h)
      38. 7.7.38 MFR_SPECIFIC_21 (OPTIONS) (E5h)
      39. 7.7.39 MFR_SPECIFIC_22 (PWM_OSC_SELECT) (E6h)
      40. 7.7.40 MFR_SPECIFIC_23 (MASK SMBALERT) (E7h)
      41. 7.7.41 MFR_SPECIFIC_25 (AVS_CONFIG) (E9h)
      42. 7.7.42 MFR_SPECIFIC_26 (AVS_ADDRESS) (EAh)
      43. 7.7.43 MFR_SPECIFIC_27 (AVS_DAC_DEFAULT) (EBh)
      44. 7.7.44 MFR_SPECIFIC_28 (AVS_CLAMP_HI) (ECh)
      45. 7.7.45 MFR_SPECIFIC_29 (AVS_CLAMP_LO) (EDh)
      46. 7.7.46 MFR_SPECIFIC_30 (TEMP_OFFSET) (EEh)
      47. 7.7.47 MFR_SPECIFIC_32 (API_OPTIONS) (F0h)
      48. 7.7.48 MFR_SPECIFIC_44 (DEVICE_CODE) (FCh)
  8. Applications and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Dual-Output Application
      2. 8.2.2 Design Requirements
      3. 8.2.3 Design Procedure
        1. 8.2.3.1  Switching Frequency Selection
        2. 8.2.3.2  Inductor Selection
        3. 8.2.3.3  Output Capacitor Selection
          1. 8.2.3.3.1 Output Voltage Deviation During Load Transient
          2. 8.2.3.3.2 Output Voltage Ripple
        4. 8.2.3.4  Input Capacitor Selection
        5. 8.2.3.5  VDD, BP5, BP3 Bypass Capacitor
        6. 8.2.3.6  R-C Snubber
        7. 8.2.3.7  Current and Temperature Sensor
        8. 8.2.3.8  Power Sequence Between the TPS40425 Device and Power Stage
        9. 8.2.3.9  Output Voltage Setting and Frequency Compensation Selection
        10. 8.2.3.10 Key PMBus Parameter Selection
          1. 8.2.3.10.1 MFR_SPECIFIC_21 (OPTIONS)
            1. 8.2.3.10.1.1 IOUT_CAL_GAIN
            2. 8.2.3.10.1.2 Enable and UVLO
            3. 8.2.3.10.1.3 Soft-Start Time
            4. 8.2.3.10.1.4 Overcurrent Threshold and Response
      4. 8.2.4 Application Curves
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
      1. 10.1.1 Layout Guidelines for TPS40425 Device
      2. 10.1.2 Layout Guidelines for Power Stage Device
    2. 10.2 Layout Example
  11. 11デバイスおよびドキュメントのサポート
    1. 11.1 デバイス・サポート
      1. 11.1.1 開発サポート
        1. 11.1.1.1 Texas Instruments Fusion Digital Power Designer
        2. 11.1.1.2 TPS40kループ補償ツール
    2. 11.2 商標
    3. 11.3 静電気放電に関する注意事項
    4. 11.4 Glossary
  12. 12メカニカル、パッケージ、および注文情報

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

CLEAR_FAULTS (03h)

Format N/A
Description CLEAR_FAULTS is a paged command. In order to issue this command for channel 1 of the TPS40425 device, PAGE must be set to 0. In order to issue this command for channel 2 of TPS40425 controller, PAGE must be set to 1. For simultaneous access of channels 1 and 2, PAGE command must be set to 11.

The CLEAR_FAULTS command is used to clear any fault bits that have been set. This command simultaneously clears all bits in all status registers in the selected PAGE. At the same time, the device negates (clears, releases) its SMB_ALERT signal output if the device is asserting the SMB_ALERT signal.

The CLEAR_FAULTS command does not cause a unit that has latched off for a fault condition to restart. If the fault is still present when the bit is cleared, the fault bit shall immediately be set again and the host notified by the usual means.
Bits Field Name Description
7:0 No data bytes are sent, only the command code is sent.