Cell chemistry Lead Acid, Li-Ion/Li-Polymer, NiCd, NiMH Number of series cells 2-4 Cells Communication interface SMBus Battery capacity (min) (mAh) 800 Battery capacity (max) (mAh) 10000 Implementation Pack External capacity indication LED Features Coulomb Counter Operating temperature range (°C) 0 to 70 Rating Catalog
Cell chemistry Lead Acid, Li-Ion/Li-Polymer, NiCd, NiMH Number of series cells 2-4 Cells Communication interface SMBus Battery capacity (min) (mAh) 800 Battery capacity (max) (mAh) 10000 Implementation Pack External capacity indication LED Features Coulomb Counter Operating temperature range (°C) 0 to 70 Rating Catalog
SOIC (D) 16 59.4 mm² 9.9 x 6
  • Provides accurate measurement of available charge in NiCd, NiMH, and Li-Ion batteries
  • Supports SBS v1.0 data set and two-wire interface
  • Monitors charge FET in Li-Ion pack protection circuit
  • Designed for battery pack integration
    - Low operating current
    - Complete circuit can fit on less than 3/4 square inch of PCB space
  • Supports SBS charge control commands for NiCd, NiMH, and Li-Ion
  • Drives a four-segment LED display for remaining capacity indication
  • 16-pin narrow SOIC
  • Provides accurate measurement of available charge in NiCd, NiMH, and Li-Ion batteries
  • Supports SBS v1.0 data set and two-wire interface
  • Monitors charge FET in Li-Ion pack protection circuit
  • Designed for battery pack integration
    - Low operating current
    - Complete circuit can fit on less than 3/4 square inch of PCB space
  • Supports SBS charge control commands for NiCd, NiMH, and Li-Ion
  • Drives a four-segment LED display for remaining capacity indication
  • 16-pin narrow SOIC

The bq2040 Gas Gauge IC With SMBus Interface is intended for battery-pack or in-system installation to maintain an accurate record of available battery charge. The bq2040 directly supports capacity monitoring for NiCd, NiMH, and Li-Ion battery chemistries.

The bq2040 uses the System Management Bus v1.0 (SMBus) protocol and supports the Smart Battery Data (SBData) commands. The bq2040 also supports the SBData charge control functions. Battery state-of-charge, remaining capacity, remaining time, and chemistry are available over the serial link. Battery-charge state can be directly indicated using a four-segment LED display to graphically depict battery full-to-empty in 25% increments.

The bq2040 estimates battery self-discharge based on an internal timer and temperature sensor and user-programmable rate information stored in external EEPROM. The bq2040 also automatically recalibrates or \x93learns\x94 battery capacity in the full course of a discharge cycle from full to empty.

The bq2040 may operate directly from three nickel chemistry cells. With the REF output and an external transistor, a simple, inexpensive regulator can be built to provide VCC for other battery cell configurations.

An external EEPROM is used to program initial values into the bq2040 and is necessary for proper operation.

The bq2040 Gas Gauge IC With SMBus Interface is intended for battery-pack or in-system installation to maintain an accurate record of available battery charge. The bq2040 directly supports capacity monitoring for NiCd, NiMH, and Li-Ion battery chemistries.

The bq2040 uses the System Management Bus v1.0 (SMBus) protocol and supports the Smart Battery Data (SBData) commands. The bq2040 also supports the SBData charge control functions. Battery state-of-charge, remaining capacity, remaining time, and chemistry are available over the serial link. Battery-charge state can be directly indicated using a four-segment LED display to graphically depict battery full-to-empty in 25% increments.

The bq2040 estimates battery self-discharge based on an internal timer and temperature sensor and user-programmable rate information stored in external EEPROM. The bq2040 also automatically recalibrates or \x93learns\x94 battery capacity in the full course of a discharge cycle from full to empty.

The bq2040 may operate directly from three nickel chemistry cells. With the REF output and an external transistor, a simple, inexpensive regulator can be built to provide VCC for other battery cell configurations.

An external EEPROM is used to program initial values into the bq2040 and is necessary for proper operation.

ダウンロード 字幕付きのビデオを表示 ビデオ

技術資料

star =TI が選定したこの製品の主要ドキュメント
結果が見つかりませんでした。検索条件をクリアしてから、再度検索を試してください。
6 をすべて表示
種類 タイトル 最新の英語版をダウンロード 日付
* データシート Gas Gauge IC With SMBus Interface データシート 1999年 9月 5日
アプリケーション・ノート Wide-Vin Battery-Charger Using SMBus MSP430 MCUs and bq Fuel Gauges (Rev. B) PDF | HTML 2019年 7月 12日
アプリケーション・ノート bq2040-D111 to bq2040-C408 Change List 2003年 10月 20日
ユーザー・ガイド bq2040 EVM 2000年 4月 10日
ユーザー・ガイド bq2040 SBS v1.0 Gas Gauge Demonstration Module 2000年 4月 10日
アプリケーション・ノート U-513 Using the bq2040, Smart Battery System Gas Gauge IC 1999年 9月 5日

設計と開発

その他のアイテムや必要なリソースを参照するには、以下のタイトルをクリックして詳細ページをご覧ください。

サポート・ソフトウェア

SLUC013 Software for the bq2040

サポート対象の製品とハードウェア

サポート対象の製品とハードウェア

製品
バッテリ残量計
BQ2040 4 個の LED ドライバ搭載、マルチケミストリー、SBS (スマート・バッテリ・システム) 1.0 準拠バッテリ残量計
パッケージ ピン数 ダウンロード
SOIC (D) 16 オプションの表示

購入と品質

記載されている情報:
  • RoHS
  • REACH
  • デバイスのマーキング
  • リード端子の仕上げ / ボールの原材料
  • MSL 定格 / ピーク リフロー
  • MTBF/FIT 推定値
  • 材質成分
  • 認定試験結果
  • 継続的な信頼性モニタ試験結果
記載されている情報:
  • ファブの拠点
  • 組み立てを実施した拠点

サポートとトレーニング

TI E2E™ フォーラムでは、TI のエンジニアからの技術サポートを提供

コンテンツは、TI 投稿者やコミュニティ投稿者によって「現状のまま」提供されるもので、TI による仕様の追加を意図するものではありません。使用条件をご確認ください。

TI 製品の品質、パッケージ、ご注文に関するお問い合わせは、TI サポートをご覧ください。​​​​​​​​​​​​​​

ビデオ